DYNISCO DYNISCO UPR800 Series Instruction Manual Wiring Scaling Connect the wires from transducer cable as shown in the terminal diagram, turn the screws with a torque between 1.0 and 1.2 Nm. Connect an appropriate length of thermocouple extension wire (Type J) to the connector. Connect the thermocouple to the appropriate terminals (remember that red is negative). Connect alarm(s) if applicable. Note that alarm defaults are High, Reverse Acting.

Connect power to the appropriate terminals as shown. Apply power to the instrument; Upper display will give a reading near zero. Lower display will read the actual temperature. Press FUNC key until the Upper display reads NONE. Lower display reads GROUP. If your transducer is not a 10,000-psi model, select Group 3 using the Up arrow, enter with function key. Lower display reads PI.FSV (Full Scale Value), and the upper display reads 10,000.

DYNISCO UPR800 Series Instruction Manual Wiring Scaling Connect the wires from transducer cable as shown in the terminal diagram. PT-100 RTD, high-level voltage. Manchu Pallaki Songs Free Download Ziddu. The PT460E Series transducer is a ±0.5% sensor ideal for melt pressure applications requiring simple. DYNISCO MODEL PT462E The Classic Flexible Stem Melt Pressure Transducer. Title: mptransducersWEB Author: daley Created Date: 10:28:12 PM.

Note: If your transducer is a 10,000 psi model skip next two steps. Scroll to GROUP.

Using the Down arrow key set the appropriate Full Scale Value for your transducer. Java Concepts Ap Computer Science 5th Edition Answers. Enter using the FUNC key to scroll until GROUP legend appears again.

Using Up arrow key, select GROUP 2. Calibration and Operation Lower display reads ZERO.C and upper display reads OFF. Be sure transducer is at operation temperature and that no pressure is applied. Change upper display to ON by using the Up arrow key. Enter with the FUNC key. After a few seconds, the lower display will show SPAN.C and upper display will show OFF. Change upper display to ON using Up arrow key.

Enter with the FUNC key. In a few seconds lower display shows DSP.FL and upper display shows 0.4. Calibration is complete. Using the FUNC key, scroll to the GROUP display.

Enter 1 with the Up arrow, and enter with the FUNC key. Instrument shows 0 (±10) on upper display and temperature on lower display. System is ready for use.

References to Profibus features and instructions should be ignored. Profibus is being considered for a future line expansion and has been accommodated in the current design. Page 6 DYNISCO UPR800 Series Instruction Manual 1.0 INTRODUCTION The UPR800 Pressure/Process Indicator is a microprocessor-based instrument, with the capability of monitoring one or two process variables simultaneously. The primary input is user configurable to be 350Ω Strain Gage, high-level voltage or high level current.

If the second input option is chosen, it is configurable by the user as any of four thermocouples, PT-100 RTD, high-level voltage or high level current. Boris Graffiti Keygen. They are compatible with many process transmitters and can be scaled by the user to give an appropriate range in engineering units. The UPR800, in its dual input version, can provide simultaneous readout of common process variable pairs such as Pressure and Temperature, Temperature and Humidity, etc., when used with the appropriate sensor / transmitter combinations. Pressure value input and retransmission output groups are selected though the keypad.